    MODELS AND SPECIFICATIONS

     

    Steps in selecting a suitable SPEEDYLECTRIC Steam Generator
     
     

     

     A
    Determine amount of steam in pounds per hour or heat in BTU's per hour needed for your application.

     B
    Ascertain maximum steam pressure required.

     C
    Refer to "Specification Chart" below.

     D
    On one of the Horizontal lines, 240V, 480V or 550V, find steam or heat output required for your application.

     E


    Catalog number of the SPEEDYLECTRIC steam generator suited to your requirements will be found under "Maximum Steam Pressure" - 15 - 100 or 150 whichever is next above the maximum pressure required.

    In Stock Safety Valves: 15, 25, 50, 100, 125, 150 psig.

     
     

    Catalog Numbers & Specifications for Utility Series Electric Boilers
     
     

     

    Maximum Steam Pressure

    Plant Power Supply

    Maximum Capacity Rating

    15 psig

    100 psig

    150 psig

    Steam Output

    Heat Output

    Electrical

    Catalog Number

    BHP

    Lbs/hr

    BTU/hr

    Amps

    Kw

    15A-2-1*

    -

    -

    240-1 V.

    1

    34

    33M

    43

    10

    15A-2

    -

    -

    240 V.

    1.5

    52

    51M

    43

    15

    15A-4

    -

    -

    480 V.

    2

    69

    67M

    25

    20

    15A-5

    -

    -

    550 V.

    2

    69

    67M

    22

    20

    -

    100A-2-1*

    150A-2-1*

    240-1 V.

    1

    34

    33M

    43

    10

    -

    100A-2

    150A-2

    240 V.

    1.5

    52

    51M

    43

    15

    -

    100A-4

    150A-4

    480 V.

    2

    69

    67M

    25

    20

    -

    100A-5

    150A-5

    550 V.

    2

    69

    67M

    22

    20

    *Single phase can be easily converted to 3 phase. 