Principles of Operation
Steam Generator Features
Models & Specifications Guide
Installation Drawings
Shipping Weights & Crate Sizes
2-14 Boiler Horsepower
Principles of Operation
Steam Generator Features
Models & Specifications Guide
Installation Drawings
Shipping Weights & Crate Sizes
1-2 Boiler Horsepower
    phone: 1-800-714-7741
e-mail:



MENU
  • Home Page
  • Contact Us


    AUTOMATIC BALANCE
    CONTROL SERIES

  • Operation
  • Features
  • Specifications
  • Installation
  • Weights & Sizes
  • 2-14 Horsepower


    UTLITITY SERIES
  • Operation
  • Features
  • Specifications
  • Installation
  • Weights & Sizes
  • 1-2 Horsepower



    PHONE:
    1-800-714-7741
    1-269-695-7741


    FAX:
    1-269-695-7777
  • AUTOMATIC BALANCE CONTROL MODELS AND SPECIFICATIONS

     

    Steps in selecting a suitable SPEEDYLECTRIC Steam Generator
     
     

     A
    Determine amount of steam in pounds per hour or heat in BTU's per hour needed for your application.

     B
    Ascertain maximum steam pressure required.

     C
    Refer to "Specification Chart" below.

     D
    On one of the Horizontal lines, 240V, 480V or 550V, find steam or heat output required for your application.

     E





    Catalog number of the SPEEDYLECTRIC steam generator or electric boiler suited to your requirements will be found under "Maximum Steam Pressure" - 15 - 100 - 150 - 200 - 240* PSIG whichever is next above the maximum pressure required.

    In Stock Safety Valves: 15, 25, 50, 100, 125, 150, 200, 240 and 250 psig.

     
     

    Specification Chart SPEEDYLECTRIC Steam Generators
     
     

    Maximum Steam Pressure

    Plant Power Supply

    Maximum Capacity Rating

    15 psig

    100 psig

    150 psig

    200 psig

    240 psig*

    Steam Output

    Heat Output

    Electrical

    Catalog Number

    BHP

    Lbs/hr

    BTU/hr

    Amps

    Kw

    15AA-2

    -

    -

    -

    -

    240 V.

    2

    69

    67M

    49

    20

    15AA-4

    -

    -

    -

    -

    480 V.

    3

    104

    101M

    37

    30

    15AA-5

    -

    -

    -

    -

    550 V.

    3

    104

    101M

    32

    30

    -

    100AA-2

    150AA-2

    200AA-2

    240AA-2

    240 V.

    2.5

    86

    84M

    62

    25

    -

    100AA-4

    150AA-4

    200AA-4

    240AA-4

    480 V.

    4

    138

    134M

    50

    40

    -

    100AA-5

    150AA-5

    200AA-5

    240AA-5

    550 V.

    4

    138

    134M

    43

    40

    15BB-2

    -

    -

    -

    -

    240 V.

    3

    104

    101M

    74

    30

    15BB-4

    -

    -

    -

    -

    480 V.

    6

    207

    201M

    74

    60

    15BB-5

    -

    -

    -

    -

    550 V.

    6

    207

    201M

    64

    60

    -

    100BB-2

    150BB-2

    200BB-2

    240BB-2

    240 V.

    3.5

    120

    117M

    86

    35

    -

    100BB-4

    150BB-4

    200BB-4

    240BB-4

    480 V.

    7

    242

    234M

    86

    70

    -

    100BB-5

    150BB-5

    200BB-5

    240BB-5

    550 V.

    7

    242

    234M

    75

    70

    15CC-2

    -

    -

    -

    -

    240 V.

    6

    207

    201M

    148

    60

    15CC-4

    -

    -

    -

    -

    480 V.

    12

    414

    402M

    148

    120

    15CC-5

    -

    -

    -

    -

    550 V.

    12

    414

    402M

    125

    120

    -

    100CC-2

    150CC-2

    200CC-2

    240CC-2

    240 V.

    7

    242

    234M

    172

    70

    -

    100CC-4

    150CC-4

    200CC-4

    240CC-4

    480 V.

    14

    483

    468M

    172

    140

    -

    100CC-5

    150CC-5

    200CC-5

    240CC-5

    550 V.

    14

    483

    468M

    150

    140

    *240 psig units can be manufactured as 250 psig units for an additional charge. 
    Foreign Voltages Available.
     
         



    Electric Boilers Assembled in the USA Assembled in the U.S.A. for over 50 years.
    automatic balance control series utility series